Tom Rini | 53633a8 | 2024-02-29 12:33:36 -0500 | [diff] [blame] | 1 | Nuvoton NPCM PWM and Fan Tacho controller device |
| 2 | |
| 3 | The Nuvoton BMC NPCM7XX supports 8 Pulse-width modulation (PWM) |
| 4 | controller outputs and 16 Fan tachometer controller inputs. |
| 5 | |
| 6 | The Nuvoton BMC NPCM8XX supports 12 Pulse-width modulation (PWM) |
| 7 | controller outputs and 16 Fan tachometer controller inputs. |
| 8 | |
| 9 | Required properties for pwm-fan node |
| 10 | - #address-cells : should be 1. |
| 11 | - #size-cells : should be 0. |
| 12 | - compatible : "nuvoton,npcm750-pwm-fan" for Poleg NPCM7XX. |
| 13 | : "nuvoton,npcm845-pwm-fan" for Arbel NPCM8XX. |
| 14 | - reg : specifies physical base address and size of the registers. |
| 15 | - reg-names : must contain: |
| 16 | * "pwm" for the PWM registers. |
| 17 | * "fan" for the Fan registers. |
| 18 | - clocks : phandle of reference clocks. |
| 19 | - clock-names : must contain |
| 20 | * "pwm" for PWM controller operating clock. |
| 21 | * "fan" for Fan controller operating clock. |
| 22 | - interrupts : contain the Fan interrupts with flags for falling edge. |
| 23 | - pinctrl-names : a pinctrl state named "default" must be defined. |
| 24 | - pinctrl-0 : phandle referencing pin configuration of the PWM and Fan |
| 25 | controller ports. |
| 26 | |
| 27 | fan subnode format: |
| 28 | =================== |
| 29 | Under fan subnode can be upto 8 child nodes, each child node representing a fan. |
| 30 | Each fan subnode must have one PWM channel and at least one Fan tach channel. |
| 31 | |
| 32 | For PWM channel can be configured cooling-levels to create cooling device. |
| 33 | Cooling device could be bound to a thermal zone for the thermal control. |
| 34 | |
| 35 | Required properties for each child node: |
| 36 | - reg : specify the PWM output channel. |
| 37 | integer value in the range 0 through 7, that represent |
| 38 | the PWM channel number that used. |
| 39 | |
| 40 | - fan-tach-ch : specify the Fan tach input channel. |
| 41 | integer value in the range 0 through 15, that represent |
| 42 | the fan tach channel number that used. |
| 43 | |
| 44 | At least one Fan tach input channel is required |
| 45 | |
| 46 | Optional property for each child node: |
| 47 | - cooling-levels: PWM duty cycle values in a range from 0 to 255 |
| 48 | which correspond to thermal cooling states. |
| 49 | |
| 50 | Examples: |
| 51 | |
| 52 | pwm_fan:pwm-fan-controller@103000 { |
| 53 | #address-cells = <1>; |
| 54 | #size-cells = <0>; |
| 55 | compatible = "nuvoton,npcm750-pwm-fan"; |
| 56 | reg = <0x103000 0x2000>, |
| 57 | <0x180000 0x8000>; |
| 58 | reg-names = "pwm", "fan"; |
| 59 | clocks = <&clk NPCM7XX_CLK_APB3>, |
| 60 | <&clk NPCM7XX_CLK_APB4>; |
| 61 | clock-names = "pwm","fan"; |
| 62 | interrupts = <GIC_SPI 96 IRQ_TYPE_LEVEL_HIGH>, |
| 63 | <GIC_SPI 97 IRQ_TYPE_LEVEL_HIGH>, |
| 64 | <GIC_SPI 98 IRQ_TYPE_LEVEL_HIGH>, |
| 65 | <GIC_SPI 99 IRQ_TYPE_LEVEL_HIGH>, |
| 66 | <GIC_SPI 100 IRQ_TYPE_LEVEL_HIGH>, |
| 67 | <GIC_SPI 101 IRQ_TYPE_LEVEL_HIGH>, |
| 68 | <GIC_SPI 102 IRQ_TYPE_LEVEL_HIGH>, |
| 69 | <GIC_SPI 103 IRQ_TYPE_LEVEL_HIGH>; |
| 70 | pinctrl-names = "default"; |
| 71 | pinctrl-0 = <&pwm0_pins &pwm1_pins &pwm2_pins |
| 72 | &fanin0_pins &fanin1_pins &fanin2_pins |
| 73 | &fanin3_pins &fanin4_pins>; |
| 74 | fan@0 { |
| 75 | reg = <0x00>; |
| 76 | fan-tach-ch = /bits/ 8 <0x00 0x01>; |
| 77 | cooling-levels = <127 255>; |
| 78 | }; |
| 79 | fan@1 { |
| 80 | reg = <0x01>; |
| 81 | fan-tach-ch = /bits/ 8 <0x02 0x03>; |
| 82 | }; |
| 83 | fan@2 { |
| 84 | reg = <0x02>; |
| 85 | fan-tach-ch = /bits/ 8 <0x04>; |
| 86 | }; |
| 87 | |
| 88 | }; |