Tom Rini | 53633a8 | 2024-02-29 12:33:36 -0500 | [diff] [blame] | 1 | Device Tree Clock bindings for cpu clock of Marvell EBU platforms |
| 2 | |
| 3 | Required properties: |
| 4 | - compatible : shall be one of the following: |
| 5 | "marvell,armada-xp-cpu-clock" - cpu clocks for Armada XP |
| 6 | "marvell,mv98dx3236-cpu-clock" - cpu clocks for 98DX3236 SoC |
| 7 | - reg : Address and length of the clock complex register set, followed |
| 8 | by address and length of the PMU DFS registers |
| 9 | - #clock-cells : should be set to 1. |
| 10 | - clocks : shall be the input parent clock phandle for the clock. |
| 11 | |
| 12 | cpuclk: clock-complex@d0018700 { |
| 13 | #clock-cells = <1>; |
| 14 | compatible = "marvell,armada-xp-cpu-clock"; |
| 15 | reg = <0xd0018700 0xA0>, <0x1c054 0x10>; |
| 16 | clocks = <&coreclk 1>; |
| 17 | } |
| 18 | |
| 19 | cpu@0 { |
| 20 | compatible = "marvell,sheeva-v7"; |
| 21 | reg = <0>; |
| 22 | clocks = <&cpuclk 0>; |
| 23 | }; |