blob: 89977b9f01cfe1ef4dade090793d7058143130e6 [file] [log] [blame]
Tom Rini93743d22024-04-01 09:08:13 -04001# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
2%YAML 1.2
3---
4$id: http://devicetree.org/schemas/iio/pressure/honeywell,hsc030pa.yaml#
5$schema: http://devicetree.org/meta-schemas/core.yaml#
6
7title: Honeywell TruStability HSC and SSC pressure sensor series
8
9description: |
10 support for Honeywell TruStability HSC and SSC digital pressure sensor
11 series.
12
13 These sensors have either an I2C, an SPI or an analog interface. Only the
14 digital versions are supported by this driver.
15
16 There are 118 models with different pressure ranges available in each family.
17 The vendor calls them "HSC series" and "SSC series". All of them have an
18 identical programming model but differ in pressure range, unit and transfer
19 function.
20
21 To support different models one needs to specify the pressure range as well
22 as the transfer function. Pressure range can either be provided via
23 pressure-triplet (directly extracted from the part number) or in case it's
24 a custom chip via numerical range limits converted to pascals.
25
26 The transfer function defines the ranges of raw conversion values delivered
27 by the sensor. pmin-pascal and pmax-pascal corespond to the minimum and
28 maximum pressure that can be measured.
29
30 Please note that in case of an SPI-based sensor, the clock signal should not
31 exceed 800kHz and the MOSI signal is not required.
32
33 Specifications about the devices can be found at:
34 https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-hsc-series/documents/sps-siot-trustability-hsc-series-high-accuracy-board-mount-pressure-sensors-50099148-a-en-ciid-151133.pdf
35 https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-ssc-series/documents/sps-siot-trustability-ssc-series-standard-accuracy-board-mount-pressure-sensors-50099533-a-en-ciid-151134.pdf
36
37maintainers:
38 - Petre Rodan <petre.rodan@subdimension.ro>
39
40properties:
41 compatible:
42 const: honeywell,hsc030pa
43
44 reg:
45 maxItems: 1
46
47 honeywell,transfer-function:
48 description: |
49 Transfer function which defines the range of valid values delivered by
50 the sensor.
51 0 - A, 10% to 90% of 2^14
52 1 - B, 5% to 95% of 2^14
53 2 - C, 5% to 85% of 2^14
54 3 - F, 4% to 94% of 2^14
55 enum: [0, 1, 2, 3]
56 $ref: /schemas/types.yaml#/definitions/uint32
57
58 honeywell,pressure-triplet:
59 description: |
60 Case-sensitive five character string that defines pressure range, unit
61 and type as part of the device nomenclature. In the unlikely case of a
62 custom chip, set to "NA" and provide pmin-pascal and pmax-pascal.
63 enum: [001BA, 1.6BA, 2.5BA, 004BA, 006BA, 010BA, 1.6MD, 2.5MD, 004MD,
64 006MD, 010MD, 016MD, 025MD, 040MD, 060MD, 100MD, 160MD, 250MD,
65 400MD, 600MD, 001BD, 1.6BD, 2.5BD, 004BD, 2.5MG, 004MG, 006MG,
66 010MG, 016MG, 025MG, 040MG, 060MG, 100MG, 160MG, 250MG, 400MG,
67 600MG, 001BG, 1.6BG, 2.5BG, 004BG, 006BG, 010BG, 100KA, 160KA,
68 250KA, 400KA, 600KA, 001GA, 160LD, 250LD, 400LD, 600LD, 001KD,
69 1.6KD, 2.5KD, 004KD, 006KD, 010KD, 016KD, 025KD, 040KD, 060KD,
70 100KD, 160KD, 250KD, 400KD, 250LG, 400LG, 600LG, 001KG, 1.6KG,
71 2.5KG, 004KG, 006KG, 010KG, 016KG, 025KG, 040KG, 060KG, 100KG,
72 160KG, 250KG, 400KG, 600KG, 001GG, 015PA, 030PA, 060PA, 100PA,
73 150PA, 0.5ND, 001ND, 002ND, 004ND, 005ND, 010ND, 020ND, 030ND,
74 001PD, 005PD, 015PD, 030PD, 060PD, 001NG, 002NG, 004NG, 005NG,
75 010NG, 020NG, 030NG, 001PG, 005PG, 015PG, 030PG, 060PG, 100PG,
76 150PG, NA]
77 $ref: /schemas/types.yaml#/definitions/string
78
79 honeywell,pmin-pascal:
80 description: |
81 Minimum pressure value the sensor can measure in pascal.
82 To be specified only if honeywell,pressure-triplet is set to "NA".
83
84 honeywell,pmax-pascal:
85 description: |
86 Maximum pressure value the sensor can measure in pascal.
87 To be specified only if honeywell,pressure-triplet is set to "NA".
88
89 vdd-supply:
90 description:
91 Provide VDD power to the sensor (either 3.3V or 5V depending on the chip)
92
93 spi-max-frequency:
94 maximum: 800000
95
96required:
97 - compatible
98 - reg
99 - honeywell,transfer-function
100 - honeywell,pressure-triplet
101
Tom Rini6bb92fc2024-05-20 09:54:58 -0600102allOf:
103 - $ref: /schemas/spi/spi-peripheral-props.yaml
104
Tom Rini93743d22024-04-01 09:08:13 -0400105additionalProperties: false
106
107dependentSchemas:
108 honeywell,pmin-pascal:
109 properties:
110 honeywell,pressure-triplet:
111 const: NA
112 honeywell,pmax-pascal:
113 properties:
114 honeywell,pressure-triplet:
115 const: NA
116
117examples:
118 - |
119 i2c {
120 #address-cells = <1>;
121 #size-cells = <0>;
122
123 pressure@28 {
124 compatible = "honeywell,hsc030pa";
125 reg = <0x28>;
126 honeywell,transfer-function = <0>;
127 honeywell,pressure-triplet = "030PA";
128 };
129 };
130 - |
131 spi {
132 #address-cells = <1>;
133 #size-cells = <0>;
134
135 pressure@0 {
136 compatible = "honeywell,hsc030pa";
137 reg = <0>;
138 spi-max-frequency = <800000>;
139 honeywell,transfer-function = <0>;
140 honeywell,pressure-triplet = "NA";
141 honeywell,pmin-pascal = <0>;
142 honeywell,pmax-pascal = <200000>;
143 };
144 };