Tom Rini | 53633a8 | 2024-02-29 12:33:36 -0500 | [diff] [blame] | 1 | * Holt HI-311X stand-alone CAN controller device tree bindings |
| 2 | |
| 3 | Required properties: |
| 4 | - compatible: Should be one of the following: |
| 5 | - "holt,hi3110" for HI-3110 |
| 6 | - reg: SPI chip select. |
| 7 | - clocks: The clock feeding the CAN controller. |
| 8 | - interrupts: Should contain IRQ line for the CAN controller. |
| 9 | |
| 10 | Optional properties: |
| 11 | - vdd-supply: Regulator that powers the CAN controller. |
| 12 | - xceiver-supply: Regulator that powers the CAN transceiver. |
| 13 | |
| 14 | Example: |
| 15 | can0: can@1 { |
| 16 | compatible = "holt,hi3110"; |
| 17 | reg = <1>; |
| 18 | clocks = <&clk32m>; |
| 19 | interrupt-parent = <&gpio4>; |
| 20 | interrupts = <13 IRQ_TYPE_LEVEL_HIGH>; |
| 21 | vdd-supply = <®5v0>; |
| 22 | xceiver-supply = <®5v0>; |
| 23 | }; |