blob: c25415d4107add09bc28d8c0f1a1546ac18b9af0 [file] [log] [blame]
Andreas Dannenberg1530e352018-08-27 15:57:43 +05301// SPDX-License-Identifier: GPL-2.0+
2/*
3 * Texas Instruments System Control Interface (TI SCI) clock driver
4 *
5 * Copyright (C) 2018 Texas Instruments Incorporated - http://www.ti.com/
6 * Andreas Dannenberg <dannenberg@ti.com>
7 *
8 * Loosely based on Linux kernel sci-clk.c...
9 */
10
11#include <common.h>
12#include <dm.h>
13#include <errno.h>
14#include <clk-uclass.h>
15#include <linux/soc/ti/ti_sci_protocol.h>
16
17/**
18 * struct ti_sci_clk_data - clock controller information structure
19 * @sci: TI SCI handle used for communication with system controller
20 */
21struct ti_sci_clk_data {
22 const struct ti_sci_handle *sci;
23};
24
25static int ti_sci_clk_probe(struct udevice *dev)
26{
27 struct ti_sci_clk_data *data = dev_get_priv(dev);
28
29 debug("%s(dev=%p)\n", __func__, dev);
30
31 if (!data)
32 return -ENOMEM;
33
34 /* Store handle for communication with the system controller */
35 data->sci = ti_sci_get_handle(dev);
36 if (IS_ERR(data->sci))
37 return PTR_ERR(data->sci);
38
39 return 0;
40}
41
42static int ti_sci_clk_of_xlate(struct clk *clk,
43 struct ofnode_phandle_args *args)
44{
45 debug("%s(clk=%p, args_count=%d)\n", __func__, clk, args->args_count);
46
47 if (args->args_count != 2) {
48 debug("Invalid args_count: %d\n", args->args_count);
49 return -EINVAL;
50 }
51
52 /*
53 * On TI SCI-based devices, the clock provider id field is used as a
54 * device ID, and the data field is used as the associated sub-ID.
55 */
56 clk->id = args->args[0];
57 clk->data = args->args[1];
58
59 return 0;
60}
61
62static int ti_sci_clk_request(struct clk *clk)
63{
64 debug("%s(clk=%p)\n", __func__, clk);
65 return 0;
66}
67
68static int ti_sci_clk_free(struct clk *clk)
69{
70 debug("%s(clk=%p)\n", __func__, clk);
71 return 0;
72}
73
74static ulong ti_sci_clk_get_rate(struct clk *clk)
75{
76 struct ti_sci_clk_data *data = dev_get_priv(clk->dev);
77 const struct ti_sci_handle *sci = data->sci;
78 const struct ti_sci_clk_ops *cops = &sci->ops.clk_ops;
79 u64 current_freq;
80 int ret;
81
82 debug("%s(clk=%p)\n", __func__, clk);
83
84 ret = cops->get_freq(sci, clk->id, clk->data, &current_freq);
85 if (ret) {
86 dev_err(clk->dev, "%s: get_freq failed (%d)\n", __func__, ret);
87 return ret;
88 }
89
90 debug("%s(current_freq=%llu)\n", __func__, current_freq);
91
92 return current_freq;
93}
94
95static ulong ti_sci_clk_set_rate(struct clk *clk, ulong rate)
96{
97 struct ti_sci_clk_data *data = dev_get_priv(clk->dev);
98 const struct ti_sci_handle *sci = data->sci;
99 const struct ti_sci_clk_ops *cops = &sci->ops.clk_ops;
100 int ret;
101
102 debug("%s(clk=%p, rate=%lu)\n", __func__, clk, rate);
103
104 /* Ask for exact frequency by using same value for min/target/max */
105 ret = cops->set_freq(sci, clk->id, clk->data, rate, rate, rate);
106 if (ret)
107 dev_err(clk->dev, "%s: set_freq failed (%d)\n", __func__, ret);
108
109 return ret;
110}
111
112static int ti_sci_clk_set_parent(struct clk *clk, struct clk *parent)
113{
114 struct ti_sci_clk_data *data = dev_get_priv(clk->dev);
115 const struct ti_sci_handle *sci = data->sci;
116 const struct ti_sci_clk_ops *cops = &sci->ops.clk_ops;
117 u8 num_parents;
118 u8 parent_cid;
119 int ret;
120
121 debug("%s(clk=%p, parent=%p)\n", __func__, clk, parent);
122
123 /* Make sure the clock parent is valid for a given device ID */
124 if (clk->id != parent->id)
125 return -EINVAL;
126
127 /* Make sure clock has parents that can be set */
128 ret = cops->get_num_parents(sci, clk->id, clk->data, &num_parents);
129 if (ret) {
130 dev_err(clk->dev, "%s: get_num_parents failed (%d)\n",
131 __func__, ret);
132 return ret;
133 }
134 if (num_parents < 2) {
135 dev_err(clk->dev, "%s: clock has no settable parents!\n",
136 __func__);
137 return -EINVAL;
138 }
139
140 /* Make sure parent clock ID is valid */
141 parent_cid = parent->data - clk->data - 1;
142 if (parent_cid >= num_parents) {
143 dev_err(clk->dev, "%s: invalid parent clock!\n", __func__);
144 return -EINVAL;
145 }
146
147 /* Ready to proceed to configure the new clock parent */
148 ret = cops->set_parent(sci, clk->id, clk->data, parent->data);
149 if (ret)
150 dev_err(clk->dev, "%s: set_parent failed (%d)\n", __func__,
151 ret);
152
153 return ret;
154}
155
156static int ti_sci_clk_enable(struct clk *clk)
157{
158 struct ti_sci_clk_data *data = dev_get_priv(clk->dev);
159 const struct ti_sci_handle *sci = data->sci;
160 const struct ti_sci_clk_ops *cops = &sci->ops.clk_ops;
161 int ret;
162
163 debug("%s(clk=%p)\n", __func__, clk);
164
165 /*
166 * Allow the System Controller to automatically manage the state of
167 * this clock. If the device is enabled, then the clock is enabled.
168 */
169 ret = cops->put_clock(sci, clk->id, clk->data);
170 if (ret)
171 dev_err(clk->dev, "%s: put_clock failed (%d)\n", __func__, ret);
172
173 return ret;
174}
175
176static int ti_sci_clk_disable(struct clk *clk)
177{
178 struct ti_sci_clk_data *data = dev_get_priv(clk->dev);
179 const struct ti_sci_handle *sci = data->sci;
180 const struct ti_sci_clk_ops *cops = &sci->ops.clk_ops;
181 int ret;
182
183 debug("%s(clk=%p)\n", __func__, clk);
184
185 /* Unconditionally disable clock, regardless of state of the device */
186 ret = cops->idle_clock(sci, clk->id, clk->data);
187 if (ret)
188 dev_err(clk->dev, "%s: idle_clock failed (%d)\n", __func__,
189 ret);
190
191 return ret;
192}
193
194static const struct udevice_id ti_sci_clk_of_match[] = {
195 { .compatible = "ti,k2g-sci-clk" },
196 { /* sentinel */ },
197};
198
199static struct clk_ops ti_sci_clk_ops = {
200 .of_xlate = ti_sci_clk_of_xlate,
201 .request = ti_sci_clk_request,
202 .free = ti_sci_clk_free,
203 .get_rate = ti_sci_clk_get_rate,
204 .set_rate = ti_sci_clk_set_rate,
205 .set_parent = ti_sci_clk_set_parent,
206 .enable = ti_sci_clk_enable,
207 .disable = ti_sci_clk_disable,
208};
209
210U_BOOT_DRIVER(ti_sci_clk) = {
211 .name = "ti-sci-clk",
212 .id = UCLASS_CLK,
213 .of_match = ti_sci_clk_of_match,
214 .probe = ti_sci_clk_probe,
215 .priv_auto_alloc_size = sizeof(struct ti_sci_clk_data),
216 .ops = &ti_sci_clk_ops,
217};