Tom Rini | 53633a8 | 2024-02-29 12:33:36 -0500 | [diff] [blame^] | 1 | // SPDX-License-Identifier: (GPL-2.0+ OR MIT) |
| 2 | /* |
| 3 | * Copyright 2022 Gateworks Corporation |
| 4 | * |
| 5 | * GW72xx RS485 HD: |
| 6 | * - GPIO1_0 rs485_term selects on-chip termination |
| 7 | * - GPIO4_0 rs485_en needs to be driven high (active) |
| 8 | * - GPIO4_2 rs485_hd needs to be driven high (active) |
| 9 | * - UART4_TX is DE for RS485 transmitter |
| 10 | * - RS485_EN needs to be pulled high |
| 11 | * - RS485_HALF needs to be pulled high |
| 12 | */ |
| 13 | |
| 14 | #include <dt-bindings/gpio/gpio.h> |
| 15 | |
| 16 | #include "imx8mm-pinfunc.h" |
| 17 | |
| 18 | /dts-v1/; |
| 19 | /plugin/; |
| 20 | |
| 21 | &{/} { |
| 22 | compatible = "gw,imx8mm-gw72xx-0x"; |
| 23 | }; |
| 24 | |
| 25 | &gpio4 { |
| 26 | rs485_en { |
| 27 | gpio-hog; |
| 28 | gpios = <0 GPIO_ACTIVE_HIGH>; |
| 29 | output-high; |
| 30 | line-name = "rs485_en"; |
| 31 | }; |
| 32 | |
| 33 | rs485_hd { |
| 34 | gpio-hog; |
| 35 | gpios = <2 GPIO_ACTIVE_HIGH>; |
| 36 | output-high; |
| 37 | line-name = "rs485_hd"; |
| 38 | }; |
| 39 | }; |
| 40 | |
| 41 | &uart2 { |
| 42 | pinctrl-names = "default"; |
| 43 | pinctrl-0 = <&pinctrl_uart2>; |
| 44 | rts-gpios = <&gpio5 29 GPIO_ACTIVE_HIGH>; |
| 45 | linux,rs485-enabled-at-boot-time; |
| 46 | status = "okay"; |
| 47 | }; |
| 48 | |
| 49 | &uart4 { |
| 50 | status = "disabled"; |
| 51 | }; |
| 52 | |
| 53 | &iomuxc { |
| 54 | pinctrl_uart2: uart2grp { |
| 55 | fsl,pins = < |
| 56 | MX8MM_IOMUXC_UART2_RXD_UART2_DCE_RX 0x140 |
| 57 | MX8MM_IOMUXC_UART2_TXD_UART2_DCE_TX 0x140 |
| 58 | MX8MM_IOMUXC_UART4_TXD_GPIO5_IO29 0x140 |
| 59 | >; |
| 60 | }; |
| 61 | }; |