blob: be51a15e05f926913b3a473648d977b25f1a2fbc [file] [log] [blame]
Tom Rini53633a82024-02-29 12:33:36 -05001-------------------------------
2BCM590xx Power Management Units
3-------------------------------
4
5Required properties:
6- compatible: "brcm,bcm59056"
7- reg: I2C slave address
8- interrupts: interrupt for the PMU. Generic interrupt client node bindings
9 are described in interrupt-controller/interrupts.txt
10
11------------------
12Voltage Regulators
13------------------
14
15Optional child nodes:
16- regulators: container node for regulators following the generic
17 regulator binding in regulator/regulator.txt
18
19 The valid regulator node names for BCM59056 are:
20 rfldo, camldo1, camldo2, simldo1, simldo2, sdldo, sdxldo,
21 mmcldo1, mmcldo2, audldo, micldo, usbldo, vibldo,
22 csr, iosr1, iosr2, msr, sdsr1, sdsr2, vsr,
23 gpldo1, gpldo2, gpldo3, gpldo4, gpldo5, gpldo6,
24 vbus
25
26Example:
27 pmu: bcm59056@8 {
28 compatible = "brcm,bcm59056";
29 reg = <0x08>;
30 interrupts = <GIC_SPI 215 IRQ_TYPE_LEVEL_HIGH>;
31 regulators {
32 rfldo_reg: rfldo {
33 regulator-min-microvolt = <1200000>;
34 regulator-max-microvolt = <3300000>;
35 };
36
37 ...
38 };