blob: 3d2fb1a7ba94804eb946a0eb3a0b07327da8239e [file] [log] [blame]
Tom Rini53633a82024-02-29 12:33:36 -05001Socionext Milbeaut UART controller
2
3Required properties:
4- compatible: should be "socionext,milbeaut-usio-uart".
5- reg: offset and length of the register set for the device.
6- interrupts: two interrupts specifier.
7- interrupt-names: should be "rx", "tx".
8- clocks: phandle to the input clock.
9
10Optional properties:
11- auto-flow-control: flow control enable.
12
13Example:
14 usio1: usio_uart@1e700010 {
15 compatible = "socionext,milbeaut-usio-uart";
16 reg = <0x1e700010 0x10>;
17 interrupts = <0 141 0x4>, <0 149 0x4>;
18 interrupt-names = "rx", "tx";
19 clocks = <&clk 2>;
20 auto-flow-control;