blob: 356cf801b4b2858818f4190c997c2bdd0f77a409 [file] [log] [blame]
# Copyright (c) 2015 Stephen Warren
# Copyright (c) 2015-2016, NVIDIA CORPORATION. All rights reserved.
#
# SPDX-License-Identifier: GPL-2.0
# Common logic to interact with U-Boot via the console. This class provides
# the interface that tests use to execute U-Boot shell commands and wait for
# their results. Sub-classes exist to perform board-type-specific setup
# operations, such as spawning a sub-process for Sandbox, or attaching to the
# serial console of real hardware.
import multiplexed_log
import os
import pytest
import re
import sys
import u_boot_spawn
# Regexes for text we expect U-Boot to send to the console.
pattern_u_boot_spl_signon = re.compile('(U-Boot SPL \\d{4}\\.\\d{2}[^\r\n]*\\))')
pattern_u_boot_main_signon = re.compile('(U-Boot \\d{4}\\.\\d{2}[^\r\n]*\\))')
pattern_stop_autoboot_prompt = re.compile('Hit any key to stop autoboot: ')
pattern_unknown_command = re.compile('Unknown command \'.*\' - try \'help\'')
pattern_error_notification = re.compile('## Error: ')
pattern_error_please_reset = re.compile('### ERROR ### Please RESET the board ###')
PAT_ID = 0
PAT_RE = 1
bad_pattern_defs = (
('spl_signon', pattern_u_boot_spl_signon),
('main_signon', pattern_u_boot_main_signon),
('stop_autoboot_prompt', pattern_stop_autoboot_prompt),
('unknown_command', pattern_unknown_command),
('error_notification', pattern_error_notification),
('error_please_reset', pattern_error_please_reset),
)
class ConsoleDisableCheck(object):
"""Context manager (for Python's with statement) that temporarily disables
the specified console output error check. This is useful when deliberately
executing a command that is known to trigger one of the error checks, in
order to test that the error condition is actually raised. This class is
used internally by ConsoleBase::disable_check(); it is not intended for
direct usage."""
def __init__(self, console, check_type):
self.console = console
self.check_type = check_type
def __enter__(self):
self.console.disable_check_count[self.check_type] += 1
self.console.eval_bad_patterns()
def __exit__(self, extype, value, traceback):
self.console.disable_check_count[self.check_type] -= 1
self.console.eval_bad_patterns()
class ConsoleSetupTimeout(object):
"""Context manager (for Python's with statement) that temporarily sets up
timeout for specific command. This is useful when execution time is greater
then default 30s."""
def __init__(self, console, timeout):
self.p = console.p
self.orig_timeout = self.p.timeout
self.p.timeout = timeout
def __enter__(self):
return self
def __exit__(self, extype, value, traceback):
self.p.timeout = self.orig_timeout
class ConsoleBase(object):
"""The interface through which test functions interact with the U-Boot
console. This primarily involves executing shell commands, capturing their
results, and checking for common error conditions. Some common utilities
are also provided too."""
def __init__(self, log, config, max_fifo_fill):
"""Initialize a U-Boot console connection.
Can only usefully be called by sub-classes.
Args:
log: A mulptiplex_log.Logfile object, to which the U-Boot output
will be logged.
config: A configuration data structure, as built by conftest.py.
max_fifo_fill: The maximum number of characters to send to U-Boot
command-line before waiting for U-Boot to echo the characters
back. For UART-based HW without HW flow control, this value
should be set less than the UART RX FIFO size to avoid
overflow, assuming that U-Boot can't keep up with full-rate
traffic at the baud rate.
Returns:
Nothing.
"""
self.log = log
self.config = config
self.max_fifo_fill = max_fifo_fill
self.logstream = self.log.get_stream('console', sys.stdout)
# Array slice removes leading/trailing quotes
self.prompt = self.config.buildconfig['config_sys_prompt'][1:-1]
self.prompt_escaped = re.escape(self.prompt)
self.p = None
self.disable_check_count = {pat[PAT_ID]: 0 for pat in bad_pattern_defs}
self.eval_bad_patterns()
self.at_prompt = False
self.at_prompt_logevt = None
def eval_bad_patterns(self):
self.bad_patterns = [pat[PAT_RE] for pat in bad_pattern_defs \
if self.disable_check_count[pat[PAT_ID]] == 0]
self.bad_pattern_ids = [pat[PAT_ID] for pat in bad_pattern_defs \
if self.disable_check_count[pat[PAT_ID]] == 0]
def close(self):
"""Terminate the connection to the U-Boot console.
This function is only useful once all interaction with U-Boot is
complete. Once this function is called, data cannot be sent to or
received from U-Boot.
Args:
None.
Returns:
Nothing.
"""
if self.p:
self.p.close()
self.logstream.close()
def run_command(self, cmd, wait_for_echo=True, send_nl=True,
wait_for_prompt=True):
"""Execute a command via the U-Boot console.
The command is always sent to U-Boot.
U-Boot echoes any command back to its output, and this function
typically waits for that to occur. The wait can be disabled by setting
wait_for_echo=False, which is useful e.g. when sending CTRL-C to
interrupt a long-running command such as "ums".
Command execution is typically triggered by sending a newline
character. This can be disabled by setting send_nl=False, which is
also useful when sending CTRL-C.
This function typically waits for the command to finish executing, and
returns the console output that it generated. This can be disabled by
setting wait_for_prompt=False, which is useful when invoking a long-
running command such as "ums".
Args:
cmd: The command to send.
wait_for_each: Boolean indicating whether to wait for U-Boot to
echo the command text back to its output.
send_nl: Boolean indicating whether to send a newline character
after the command string.
wait_for_prompt: Boolean indicating whether to wait for the
command prompt to be sent by U-Boot. This typically occurs
immediately after the command has been executed.
Returns:
If wait_for_prompt == False:
Nothing.
Else:
The output from U-Boot during command execution. In other
words, the text U-Boot emitted between the point it echod the
command string and emitted the subsequent command prompts.
"""
if self.at_prompt and \
self.at_prompt_logevt != self.logstream.logfile.cur_evt:
self.logstream.write(self.prompt, implicit=True)
try:
self.at_prompt = False
if send_nl:
cmd += '\n'
while cmd:
# Limit max outstanding data, so UART FIFOs don't overflow
chunk = cmd[:self.max_fifo_fill]
cmd = cmd[self.max_fifo_fill:]
self.p.send(chunk)
if not wait_for_echo:
continue
chunk = re.escape(chunk)
chunk = chunk.replace('\\\n', '[\r\n]')
m = self.p.expect([chunk] + self.bad_patterns)
if m != 0:
self.at_prompt = False
raise Exception('Bad pattern found on console: ' +
self.bad_pattern_ids[m - 1])
if not wait_for_prompt:
return
m = self.p.expect([self.prompt_escaped] + self.bad_patterns)
if m != 0:
self.at_prompt = False
raise Exception('Bad pattern found on console: ' +
self.bad_pattern_ids[m - 1])
self.at_prompt = True
self.at_prompt_logevt = self.logstream.logfile.cur_evt
# Only strip \r\n; space/TAB might be significant if testing
# indentation.
return self.p.before.strip('\r\n')
except Exception as ex:
self.log.error(str(ex))
self.cleanup_spawn()
raise
def run_command_list(self, cmds):
"""Run a list of commands.
This is a helper function to call run_command() with default arguments
for each command in a list.
Args:
cmd: List of commands (each a string).
Returns:
Combined output of all commands, as a string.
"""
output = ''
for cmd in cmds:
output += self.run_command(cmd)
return output
def ctrlc(self):
"""Send a CTRL-C character to U-Boot.
This is useful in order to stop execution of long-running synchronous
commands such as "ums".
Args:
None.
Returns:
Nothing.
"""
self.log.action('Sending Ctrl-C')
self.run_command(chr(3), wait_for_echo=False, send_nl=False)
def wait_for(self, text):
"""Wait for a pattern to be emitted by U-Boot.
This is useful when a long-running command such as "dfu" is executing,
and it periodically emits some text that should show up at a specific
location in the log file.
Args:
text: The text to wait for; either a string (containing raw text,
not a regular expression) or an re object.
Returns:
Nothing.
"""
if type(text) == type(''):
text = re.escape(text)
m = self.p.expect([text] + self.bad_patterns)
if m != 0:
raise Exception('Bad pattern found on console: ' +
self.bad_pattern_ids[m - 1])
def drain_console(self):
"""Read from and log the U-Boot console for a short time.
U-Boot's console output is only logged when the test code actively
waits for U-Boot to emit specific data. There are cases where tests
can fail without doing this. For example, if a test asks U-Boot to
enable USB device mode, then polls until a host-side device node
exists. In such a case, it is useful to log U-Boot's console output
in case U-Boot printed clues as to why the host-side even did not
occur. This function will do that.
Args:
None.
Returns:
Nothing.
"""
# If we are already not connected to U-Boot, there's nothing to drain.
# This should only happen when a previous call to run_command() or
# wait_for() failed (and hence the output has already been logged), or
# the system is shutting down.
if not self.p:
return
orig_timeout = self.p.timeout
try:
# Drain the log for a relatively short time.
self.p.timeout = 1000
# Wait for something U-Boot will likely never send. This will
# cause the console output to be read and logged.
self.p.expect(['This should never match U-Boot output'])
except u_boot_spawn.Timeout:
pass
finally:
self.p.timeout = orig_timeout
def ensure_spawned(self):
"""Ensure a connection to a correctly running U-Boot instance.
This may require spawning a new Sandbox process or resetting target
hardware, as defined by the implementation sub-class.
This is an internal function and should not be called directly.
Args:
None.
Returns:
Nothing.
"""
if self.p:
return
try:
self.log.start_section('Starting U-Boot')
self.at_prompt = False
self.p = self.get_spawn()
# Real targets can take a long time to scroll large amounts of
# text if LCD is enabled. This value may need tweaking in the
# future, possibly per-test to be optimal. This works for 'help'
# on board 'seaboard'.
if not self.config.gdbserver:
self.p.timeout = 30000
self.p.logfile_read = self.logstream
bcfg = self.config.buildconfig
config_spl = bcfg.get('config_spl', 'n') == 'y'
config_spl_serial_support = bcfg.get('config_spl_serial_support',
'n') == 'y'
env_spl_skipped = self.config.env.get('env__spl_skipped',
False)
if config_spl and config_spl_serial_support and not env_spl_skipped:
m = self.p.expect([pattern_u_boot_spl_signon] +
self.bad_patterns)
if m != 0:
raise Exception('Bad pattern found on SPL console: ' +
self.bad_pattern_ids[m - 1])
m = self.p.expect([pattern_u_boot_main_signon] + self.bad_patterns)
if m != 0:
raise Exception('Bad pattern found on console: ' +
self.bad_pattern_ids[m - 1])
self.u_boot_version_string = self.p.after
while True:
m = self.p.expect([self.prompt_escaped,
pattern_stop_autoboot_prompt] + self.bad_patterns)
if m == 0:
break
if m == 1:
self.p.send(' ')
continue
raise Exception('Bad pattern found on console: ' +
self.bad_pattern_ids[m - 2])
self.at_prompt = True
self.at_prompt_logevt = self.logstream.logfile.cur_evt
except Exception as ex:
self.log.error(str(ex))
self.cleanup_spawn()
raise
finally:
self.log.end_section('Starting U-Boot')
def cleanup_spawn(self):
"""Shut down all interaction with the U-Boot instance.
This is used when an error is detected prior to re-establishing a
connection with a fresh U-Boot instance.
This is an internal function and should not be called directly.
Args:
None.
Returns:
Nothing.
"""
try:
if self.p:
self.p.close()
except:
pass
self.p = None
def get_spawn_output(self):
"""Return the start-up output from U-Boot
Returns:
The output produced by ensure_spawed(), as a string.
"""
if self.p:
return self.p.get_expect_output()
return None
def validate_version_string_in_text(self, text):
"""Assert that a command's output includes the U-Boot signon message.
This is primarily useful for validating the "version" command without
duplicating the signon text regex in a test function.
Args:
text: The command output text to check.
Returns:
Nothing. An exception is raised if the validation fails.
"""
assert(self.u_boot_version_string in text)
def disable_check(self, check_type):
"""Temporarily disable an error check of U-Boot's output.
Create a new context manager (for use with the "with" statement) which
temporarily disables a particular console output error check.
Args:
check_type: The type of error-check to disable. Valid values may
be found in self.disable_check_count above.
Returns:
A context manager object.
"""
return ConsoleDisableCheck(self, check_type)
def temporary_timeout(self, timeout):
"""Temporarily set up different timeout for commands.
Create a new context manager (for use with the "with" statement) which
temporarily change timeout.
Args:
timeout: Time in milliseconds.
Returns:
A context manager object.
"""
return ConsoleSetupTimeout(self, timeout)