| if OMAP54XX |
| |
| config DRA7XX |
| bool |
| help |
| DRA7xx is an OMAP based SOC with Dual Core A-15s. |
| |
| choice |
| prompt "OMAP5 board select" |
| optional |
| |
| config TARGET_CL_SOM_AM57X |
| bool "CompuLab CL-SOM-AM57x" |
| select DRA7XX |
| |
| config TARGET_CM_T54 |
| bool "CompuLab CM-T54" |
| |
| config TARGET_OMAP5_UEVM |
| bool "TI OMAP5 uEVM board" |
| |
| config TARGET_DRA7XX_EVM |
| bool "TI DRA7XX" |
| select BOARD_LATE_INIT |
| select DRA7XX |
| select TI_I2C_BOARD_DETECT |
| select PHYS_64BIT |
| imply SCSI |
| imply DM_PMIC |
| imply PMIC_LP87565 |
| imply DM_REGULATOR |
| imply DM_REGULATOR_LP87565 |
| |
| config TARGET_AM57XX_EVM |
| bool "AM57XX" |
| select BOARD_LATE_INIT |
| select DRA7XX |
| select TI_I2C_BOARD_DETECT |
| imply SCSI |
| |
| endchoice |
| |
| config SYS_SOC |
| default "omap5" |
| |
| config OMAP_PLATFORM_RESET_TIME_MAX_USEC |
| int "Something" |
| range 0 31219 |
| default 31219 |
| help |
| Most OMAPs' provide a way to specify the time for which the reset |
| should be held low while the voltages and Oscillator outputs |
| stabilize. |
| This time is mostly board and PMIC dependent. Hence the boards are |
| expected to specify a pre-computed time using the above option. |
| This value can be computed using a summation of the below 3 |
| parameters |
| 1: Time taken by the Osciallator to stop and restart |
| 2: PMIC OTP time |
| 3: Voltage ramp time, which can be derived using the PMIC slew rate |
| and value of voltage ramp needed. |
| |
| if TARGET_DRA7XX_EVM || TARGET_AM57XX_EVM |
| menu "Voltage Domain OPP selections" |
| |
| choice |
| prompt "MPU Voltage Domain" |
| default DRA7_MPU_OPP_NOM |
| help |
| Select the Operating Performance Point(OPP) for the MPU voltage |
| domain on DRA7xx & AM57xx SoCs. |
| |
| config DRA7_MPU_OPP_NOM |
| bool "OPP NOM" |
| help |
| This config option enables Normal OPP for MPU. This is the safest |
| option for booting. |
| |
| endchoice |
| |
| choice |
| prompt "DSPEVE Voltage Domain" |
| help |
| Select the Operating Performance Point(OPP) for the DSPEVE voltage |
| domain on DRA7xx & AM57xx SoCs. |
| |
| config DRA7_DSPEVE_OPP_NOM |
| bool "OPP NOM" |
| help |
| This config option enables Normal OPP for DSPEVE. This is the safest |
| option for booting and choose this when unsure about other OPPs . |
| |
| config DRA7_DSPEVE_OPP_OD |
| bool "OPP OD" |
| help |
| This config option enables Over drive OPP for DSPEVE. |
| |
| config DRA7_DSPEVE_OPP_HIGH |
| bool "OPP HIGH" |
| help |
| This config option enables High OPP for DSPEVE. |
| |
| endchoice |
| |
| choice |
| prompt "IVA Voltage Domain" |
| help |
| Select the Operating Performance Point(OPP) for the IVA voltage |
| domain on DRA7xx & AM57xx SoCs. |
| |
| config DRA7_IVA_OPP_NOM |
| bool "OPP NOM" |
| help |
| This config option enables Normal OPP for IVA. This is the safest |
| option for booting and choose this when unsure about other OPPs . |
| |
| config DRA7_IVA_OPP_OD |
| bool "OPP OD" |
| help |
| This config option enables Over drive OPP for IVA. |
| |
| config DRA7_IVA_OPP_HIGH |
| bool "OPP HIGH" |
| help |
| This config option enables High OPP for IVA. |
| |
| endchoice |
| |
| choice |
| prompt "GPU Voltage Domain" |
| help |
| Select the Operating Performance Point(OPP) for the GPU voltage |
| domain on DRA7xx & AM57xx SoCs. |
| |
| config DRA7_GPU_OPP_NOM |
| bool "OPP NOM" |
| help |
| This config option enables Normal OPP for GPU. This is the safest |
| option for booting and choose this when unsure about other OPPs . |
| |
| config DRA7_GPU_OPP_OD |
| bool "OPP OD" |
| help |
| This config option enables Over drive OPP for GPU. |
| |
| config DRA7_GPU_OPP_HIGH |
| bool "OPP HIGH" |
| help |
| This config option enables High OPP for GPU. |
| |
| endchoice |
| |
| endmenu |
| endif |
| |
| source "board/compulab/cl-som-am57x/Kconfig" |
| source "board/compulab/cm_t54/Kconfig" |
| source "board/ti/omap5_uevm/Kconfig" |
| source "board/ti/dra7xx/Kconfig" |
| source "board/ti/am57xx/Kconfig" |
| |
| endif |