| * Copyright (C) 2018 Marvell International Ltd. |
| * |
| * SPDX-License-Identifier: BSD-3-Clause |
| * https://spdx.org/licenses |
| */ |
| |
| #include <a8k_plat_def.h> |
| #include <aro.h> |
| #include <delay_timer.h> |
| #include <mmio.h> |
| |
| /* Notify bootloader on DRAM setup */ |
| #define AP807_CPU_ARO_CTRL(cluster) \ |
| (MVEBU_RFU_BASE + 0x82A8 + (0xA58 * (cluster))) |
| |
| /* 0 - ARO clock is enabled, 1 - ARO clock is disabled */ |
| #define AP807_CPU_ARO_CLK_EN_OFFSET 0 |
| #define AP807_CPU_ARO_CLK_EN_MASK (0x1 << AP807_CPU_ARO_CLK_EN_OFFSET) |
| |
| /* 0 - ARO is the clock source, 1 - PLL is the clock source */ |
| #define AP807_CPU_ARO_SEL_PLL_OFFSET 5 |
| #define AP807_CPU_ARO_SEL_PLL_MASK (0x1 << AP807_CPU_ARO_SEL_PLL_OFFSET) |
| |
| /* AP807 clusters count */ |
| #define AP807_CLUSTER_NUM 2 |
| |
| /* PLL frequency values */ |
| #define PLL_FREQ_1200 0x2AE5F002 /* 1200 */ |
| #define PLL_FREQ_2000 0x2FC9F002 /* 2000 */ |
| #define PLL_FREQ_2200 0x2AC57001 /* 2200 */ |
| #define PLL_FREQ_2400 0x2AE5F001 /* 2400 */ |
| |
| /* CPU PLL control registers */ |
| #define AP807_CPU_PLL_CTRL(cluster) \ |
| (MVEBU_RFU_BASE + 0x82E0 + (0x8 * (cluster))) |
| |
| #define AP807_CPU_PLL_PARAM(cluster) AP807_CPU_PLL_CTRL(cluster) |
| #define AP807_CPU_PLL_CFG(cluster) (AP807_CPU_PLL_CTRL(cluster) + 0x4) |
| #define AP807_CPU_PLL_CFG_BYPASS_MODE (0x1) |
| #define AP807_CPU_PLL_CFG_USE_REG_FILE (0x1 << 9) |
| |
| static void pll_set_freq(unsigned int freq_val) |
| { |
| int i; |
| |
| for (i = 0 ; i < AP807_CLUSTER_NUM ; i++) { |
| mmio_write_32(AP807_CPU_PLL_CFG(i), |
| AP807_CPU_PLL_CFG_USE_REG_FILE); |
| mmio_write_32(AP807_CPU_PLL_CFG(i), |
| AP807_CPU_PLL_CFG_USE_REG_FILE | |
| AP807_CPU_PLL_CFG_BYPASS_MODE); |
| mmio_write_32(AP807_CPU_PLL_PARAM(i), freq_val); |
| mmio_write_32(AP807_CPU_PLL_CFG(i), |
| AP807_CPU_PLL_CFG_USE_REG_FILE); |
| } |
| } |
| |
| /* Switch to ARO from PLL in ap807 */ |
| static void aro_to_pll(void) |
| { |
| unsigned int reg; |
| int i; |
| |
| for (i = 0 ; i < AP807_CLUSTER_NUM ; i++) { |
| /* switch from ARO to PLL */ |
| reg = mmio_read_32(AP807_CPU_ARO_CTRL(i)); |
| reg |= AP807_CPU_ARO_SEL_PLL_MASK; |
| mmio_write_32(AP807_CPU_ARO_CTRL(i), reg); |
| |
| mdelay(100); |
| |
| /* disable ARO clk driver */ |
| reg = mmio_read_32(AP807_CPU_ARO_CTRL(i)); |
| reg |= (AP807_CPU_ARO_CLK_EN_MASK); |
| mmio_write_32(AP807_CPU_ARO_CTRL(i), reg); |
| } |
| } |
| |
| /* switch from ARO to PLL |
| * in case of default frequency option, configure PLL registers |
| * to be aligned with new default frequency. |
| */ |
| void ap807_clocks_init(unsigned int freq_option) |
| { |
| /* Switch from ARO to PLL */ |
| aro_to_pll(); |
| |
| /* Modifications in frequency table: |
| * 0x0: 764x: change to 2000 MHz. |
| * 0x2: 744x change to 1800 MHz, 764x change to 2200/2400. |
| * 0x3: 3900/744x/764x change to 1200 MHz. |
| */ |
| switch (freq_option) { |
| case CPU_2000_DDR_1200_RCLK_1200: |
| pll_set_freq(PLL_FREQ_2000); |
| break; |
| default: |
| break; |
| } |
| } |