commit | fed211f328f3b6dc8af6071b0ccd949d98a6b0e6 | [log] [tgz] |
---|---|---|
author | Peng Fan <peng.fan@nxp.com> | Sun May 03 22:19:51 2020 +0800 |
committer | Stefano Babic <sbabic@denx.de> | Sun May 10 20:55:20 2020 +0200 |
tree | a10fc20aead57619383cb3ecfa74ee0721eb4dab | |
parent | 6eff28790b7d000e69667950158f6975560f0ceb [diff] |
thermal: imx_tmu: support i.MX8MP Support i.MX8MP thermal which has two probes and supports temperature range from -40 to 125. Still uses default 1p HW calibration at 25C and loads calibration parameters from fuse. Signed-off-by: Ye Li <ye.li@nxp.com> Signed-off-by: Peng Fan <peng.fan@nxp.com>