ARM: DRA7: Redefine voltage and efuse macros per OPP using Kconfig

Redefine the macros used to define the voltage values and the
efuse register offsets based on OPP for all the voltage domains.
This is done using Kconfig macros that can be set in a defconfig
or selected during a config step. This allows a voltage domain
to be configured/set to a corresponding voltage value depending
on the OPP selection choice.

The Kconfig choices have been added for MPU, DSPEVE, IVA and GPU
voltage domains, with the MPU domain restricted to OPP_NOM. The
OPP_OD and OPP_HIGH options will be added when the support for
configuring the MPU clock frequency is added. The clock
configuration for other voltage domains is out of scope in
u-boot code.

The CORE voltage domain does not have separate voltage values
and efuse register offset at different OPPs, while the MPU
voltage domain only has different efuse register offsets for
different OPPs, but uses the same voltage value. Any different
choices of OPPs for voltage domains on common ganged-rails
is automatically taken care to select the corresponding
highest OPP voltage value.

Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
diff --git a/arch/arm/mach-omap2/omap5/Kconfig b/arch/arm/mach-omap2/omap5/Kconfig
index 22259dc..018e584 100644
--- a/arch/arm/mach-omap2/omap5/Kconfig
+++ b/arch/arm/mach-omap2/omap5/Kconfig
@@ -86,6 +86,99 @@
 	  using hardware memory firewalls. This value must be smaller than the
 	  TI_SECURE_EMIF_TOTAL_REGION_SIZE value.
 
+if TARGET_DRA7XX_EVM || TARGET_AM57XX_EVM
+menu "Voltage Domain OPP selections"
+
+choice
+	prompt "MPU Voltage Domain"
+	default DRA7_MPU_OPP_NOM
+        help
+	  Select the Operating Performance Point(OPP) for the MPU voltage
+	  domain on DRA7xx & AM57xx SoCs.
+
+config DRA7_MPU_OPP_NOM
+	bool "OPP NOM"
+	help
+	  This config option enables Normal OPP for MPU. This is the safest
+	  option for booting.
+
+endchoice
+
+choice
+	prompt "DSPEVE Voltage Domain"
+        help
+	  Select the Operating Performance Point(OPP) for the DSPEVE voltage
+	  domain on DRA7xx & AM57xx SoCs.
+
+config DRA7_DSPEVE_OPP_NOM
+	bool "OPP NOM"
+	help
+	  This config option enables Normal OPP for DSPEVE. This is the safest
+	  option for booting and choose this when unsure about other OPPs .
+
+config DRA7_DSPEVE_OPP_OD
+	bool "OPP OD"
+	help
+	  This config option enables Over drive OPP for DSPEVE.
+
+config DRA7_DSPEVE_OPP_HIGH
+	bool "OPP HIGH"
+	help
+	  This config option enables High OPP for DSPEVE.
+
+endchoice
+
+choice
+	prompt "IVA Voltage Domain"
+        help
+	  Select the Operating Performance Point(OPP) for the IVA voltage
+	  domain on DRA7xx & AM57xx SoCs.
+
+config DRA7_IVA_OPP_NOM
+	bool "OPP NOM"
+	help
+	  This config option enables Normal OPP for IVA. This is the safest
+	  option for booting and choose this when unsure about other OPPs .
+
+config DRA7_IVA_OPP_OD
+	bool "OPP OD"
+	help
+	  This config option enables Over drive OPP for IVA.
+
+config DRA7_IVA_OPP_HIGH
+	bool "OPP HIGH"
+	help
+	  This config option enables High OPP for IVA.
+
+endchoice
+
+choice
+	prompt "GPU Voltage Domain"
+        help
+	  Select the Operating Performance Point(OPP) for the GPU voltage
+	  domain on DRA7xx & AM57xx SoCs.
+
+config DRA7_GPU_OPP_NOM
+	bool "OPP NOM"
+	help
+	  This config option enables Normal OPP for GPU. This is the safest
+	  option for booting and choose this when unsure about other OPPs .
+
+config DRA7_GPU_OPP_OD
+	bool "OPP OD"
+	help
+	  This config option enables Over drive OPP for GPU.
+
+config DRA7_GPU_OPP_HIGH
+	bool "OPP HIGH"
+	help
+	  This config option enables High OPP for GPU.
+
+endchoice
+
+endmenu
+endif
+
 source "board/compulab/cm_t54/Kconfig"