ARM: tegra: Support TZ-only access to PMC

Some devices may restrict access to the PMC to TrustZone software only.
Non-TZ software can detect this and use SMC calls to the firmware that
runs in the TrustZone to perform accesses to PMC registers.

Note that this also fixes reset_cpu() and the enterrcm command on
Tegra186 where they were previously trying to access the PMC at a wrong
physical address.

Based on work by Kalyani Chidambaram <kalyanic@nvidia.com> and Tom
Warren <twarren@nvidia.com>.

Signed-off-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Tom Warren <twarren@nvidia.com>
diff --git a/arch/arm/mach-tegra/cmd_enterrcm.c b/arch/arm/mach-tegra/cmd_enterrcm.c
index 4e6beb3..4a889f0 100644
--- a/arch/arm/mach-tegra/cmd_enterrcm.c
+++ b/arch/arm/mach-tegra/cmd_enterrcm.c
@@ -1,6 +1,6 @@
 // SPDX-License-Identifier: GPL-2.0+
 /*
- * Copyright (c) 2012, NVIDIA CORPORATION.  All rights reserved.
+ * Copyright (c) 2012-2019, NVIDIA CORPORATION. All rights reserved.
  *
  * Derived from code (arch/arm/lib/reset.c) that is:
  *
@@ -31,12 +31,10 @@
 static int do_enterrcm(cmd_tbl_t *cmdtp, int flag, int argc,
 		       char * const argv[])
 {
-	struct pmc_ctlr *pmc = (struct pmc_ctlr *)NV_PA_PMC_BASE;
-
 	puts("Entering RCM...\n");
 	udelay(50000);
 
-	pmc->pmc_scratch0 = 2;
+	tegra_pmc_writel(2, PMC_SCRATCH0);
 	disable_interrupts();
 	reset_cpu(0);