rockchip: rk3328: Set efuse auto mode and timing control

Reading from efuse return zero when mainline TF-A is used.

  => dump_efuse
  00000000: 00 00 00 00  ....
  00000004: 00 00 00 00  ....
  00000008: 00 00 00 00  ....
  0000000c: 00 00 00 00  ....
  00000010: 00 00 00 00  ....
  00000014: 00 00 00 00  ....
  00000018: 00 00 00 00  ....
  0000001c: 00 00 00 00  ....

However, when vendor TF-A blobs is used reading from efuse works.

Change to use auto mode, enable finish and auto access err interrupts
and set timing control using same values that vendor TF-A blob use to
fix this.

With this efuse can be read when either of mainline TF-A or vendor blob
is used.

  => dump_efuse
  00000000: 52 4b 33 82  RK3.
  00000004: 00 fe 21 55  ..!U
  00000008: 52 4b 57 34  RKW4
  0000000c: 35 30 32 39  5029
  00000010: 00 00 00 00  ....
  00000014: 08 25 0c 0f  .%..
  00000018: 02 0d 08 00  ....
  0000001c: 00 00 f0 00  ....

Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
1 file changed