power: axp209: Limit inrush current for broken boards
Some boards feature a capacitance on LDO3's output that is too large,
causing inrush currents which as a result, shut down the AXP209. This
has been reported before, without knowing the actual cause.
A fix appeared to be done with
commit 0e6e34ac8dbb ("sunxi: Olimex A20 boards: Enable LDO3 and LDO4 regulators").
The description there is a bit misleading, the kernel does not hang
during AXP209 initialization, the PMIC shuts down, causing voltages to
drop and thus the whole system freezes.
While the AXP209 does have the ability to ramp up the voltage slowly, to
reduce these inrush currents, the voltage rate control (VRC) however is
not applicable when switching on the LDO3 output. Only when going from
an enabled lower voltage setting, to a higher voltage setting is the VRC
in effect.
To work around this problem, we set LDO3 to the lowest possible setting
of 0.7 V if it was not yet enabled, and then let the VRC (if enabled) do
its thing. It should be noted, that for some undocumented reason, there
is a short delay needed between setting the LDO3 voltage register and
enabling the power. One would expect that this delay ought to be just
after enabling the output power at 0.7 V, but this did not work.
Signed-off-by: Olliver Schinagl <oliver@schinagl.nl>
Signed-off-by: Priit Laes <plaes@plaes.org>
Acked-by: Maxime Ripard <maxime.ripard@bootlin.com>
diff --git a/drivers/power/axp209.c b/drivers/power/axp209.c
index cf138fc..67b4209 100644
--- a/drivers/power/axp209.c
+++ b/drivers/power/axp209.c
@@ -122,6 +122,29 @@
if (rc)
return rc;
+#ifdef CONFIG_AXP_ALDO3_INRUSH_QUIRK
+ /*
+ * On some boards, LDO3 has a too big capacitor installed. When
+ * turning on LDO3, this causes the AXP209 to shutdown on
+ * voltages over 1.9 volt. As a workaround, we enable LDO3
+ * first with the lowest possible voltage. If this still causes
+ * high inrush currents, the voltage slope should be increased.
+ */
+ rc = pmic_bus_read(AXP209_OUTPUT_CTRL, &cfg);
+ if (rc)
+ return rc;
+
+ if (!(cfg & AXP209_OUTPUT_CTRL_LDO3)) {
+ rc = pmic_bus_write(AXP209_LDO3_VOLTAGE, 0x0); /* 0.7 Volt */
+ mdelay(1);
+ rc |= pmic_bus_setbits(AXP209_OUTPUT_CTRL,
+ AXP209_OUTPUT_CTRL_LDO3);
+
+ if (rc)
+ return rc;
+ }
+#endif
+
if (mvolt == -1) {
cfg = AXP209_LDO3_VOLTAGE_FROM_LDO3IN;
} else {