net: phy: meson-gxl: detect LPA corruption

This patch is ported from the Linux patch posted at [1] and applied to
net tree as commit f1e2400a80ff.

The purpose of this change is to fix the incorrect detection of the link
partner (LP) advertised capabilities which sometimes happens with this PHY
(roughly 1 time in a dozen)

This issue may cause the link to be negotiated at 10Mbps/Full or
10Mbps/Half when 100MBps/Full is actually possible. In some case, the link
is even completely broken and no communication is possible.

To detect the corruption, we must look for a magic undocumented bit in the
WOL bank (hint given by the SoC vendor kernel) but this is not enough to
cover all cases. We also have to look at the LPA ack. If the LP supports
Aneg but did not ack our base code when aneg is completed, we assume
something went wrong.

The detection of a corrupted LPA triggers a restart of the aneg process.
This solves the problem but may take up to 6 retries to complete.

[1] https://lkml.kernel.org/r/20171208110811.30789-1-jbrunet@baylibre.com

Fixes: 8995a96d1d67 ("net: phy: Add Amlogic Meson GXL Internal PHY support")
Signed-off-by: Jerome Brunet <jbrunet@baylibre.com>
Signed-off-by: Neil Armstrong <narmstrong@baylibre.com>
diff --git a/drivers/net/phy/meson-gxl.c b/drivers/net/phy/meson-gxl.c
index ccf70c9..5f4ecb1 100644
--- a/drivers/net/phy/meson-gxl.c
+++ b/drivers/net/phy/meson-gxl.c
@@ -10,8 +10,94 @@
 #include <config.h>
 #include <common.h>
 #include <linux/bitops.h>
+#include <dm.h>
 #include <phy.h>
 
+/* This function is provided to cope with the possible failures of this phy
+ * during aneg process. When aneg fails, the PHY reports that aneg is done
+ * but the value found in MII_LPA is wrong:
+ *  - Early failures: MII_LPA is just 0x0001. if MII_EXPANSION reports that
+ *    the link partner (LP) supports aneg but the LP never acked our base
+ *    code word, it is likely that we never sent it to begin with.
+ *  - Late failures: MII_LPA is filled with a value which seems to make sense
+ *    but it actually is not what the LP is advertising. It seems that we
+ *    can detect this using a magic bit in the WOL bank (reg 12 - bit 12).
+ *    If this particular bit is not set when aneg is reported being done,
+ *    it means MII_LPA is likely to be wrong.
+ *
+ * In both case, forcing a restart of the aneg process solve the problem.
+ * When this failure happens, the first retry is usually successful but,
+ * in some cases, it may take up to 6 retries to get a decent result
+ */
+int meson_gxl_startup(struct phy_device *phydev)
+{
+	unsigned int retries = 10;
+	int ret, wol, lpa, exp;
+
+restart_aneg:
+	ret = genphy_update_link(phydev);
+	if (ret)
+		return ret;
+
+	if (phydev->autoneg == AUTONEG_ENABLE) {
+		/* Need to access WOL bank, make sure the access is open */
+		ret = phy_write(phydev, MDIO_DEVAD_NONE, 0x14, 0x0000);
+		if (ret)
+			return ret;
+		ret = phy_write(phydev, MDIO_DEVAD_NONE, 0x14, 0x0400);
+		if (ret)
+			return ret;
+		ret = phy_write(phydev, MDIO_DEVAD_NONE, 0x14, 0x0000);
+		if (ret)
+			return ret;
+		ret = phy_write(phydev, MDIO_DEVAD_NONE, 0x14, 0x0400);
+		if (ret)
+			return ret;
+
+		/* Request LPI_STATUS WOL register */
+		ret = phy_write(phydev, MDIO_DEVAD_NONE, 0x14, 0x8D80);
+		if (ret)
+			return ret;
+
+		/* Read LPI_STATUS value */
+		wol = phy_read(phydev, MDIO_DEVAD_NONE, 0x15);
+		if (wol < 0)
+			return wol;
+
+		lpa = phy_read(phydev, MDIO_DEVAD_NONE, MII_LPA);
+		if (lpa < 0)
+			return lpa;
+
+		exp = phy_read(phydev, MDIO_DEVAD_NONE, MII_EXPANSION);
+		if (exp < 0)
+			return exp;
+
+		if (!(wol & BIT(12)) ||
+			((exp & EXPANSION_NWAY) && !(lpa & LPA_LPACK))) {
+			
+			/* Looks like aneg failed after all */
+			if (!retries) {
+				printf("%s LPA corruption max attempts\n",
+					phydev->dev->name);
+				return -ETIMEDOUT;
+			}
+
+			printf("%s LPA corruption - aneg restart\n",
+				phydev->dev->name);
+
+			ret = genphy_restart_aneg(phydev);
+			if (ret)
+				return ret;
+
+			--retries;
+
+			goto restart_aneg;
+		}
+	}
+
+	return genphy_parse_link(phydev);
+}
+
 static int meson_gxl_phy_config(struct phy_device *phydev)
 {
 	/* Enable Analog and DSP register Bank access by */
@@ -45,7 +131,7 @@
 	.mask = 0xfffffff0,
 	.features = PHY_BASIC_FEATURES,
 	.config = &meson_gxl_phy_config,
-	.startup = &genphy_startup,
+	.startup = &meson_gxl_startup,
 	.shutdown = &genphy_shutdown,
 };