net: mdio: Use mb() to be compatible for both ARM and PowerPC
Use mb() instead of sync assembly instruction to be
compatible for both ARM and PowerPC.
Signed-off-by: Alison Wang <alison.wang@freescale.com>
diff --git a/drivers/net/fsl_mdio.c b/drivers/net/fsl_mdio.c
index 8d09f5d..d6b181b 100644
--- a/drivers/net/fsl_mdio.c
+++ b/drivers/net/fsl_mdio.c
@@ -19,7 +19,8 @@
out_be32(&phyregs->miimadd, (port_addr << 8) | (regnum & 0x1f));
out_be32(&phyregs->miimcon, value);
- asm("sync");
+ /* Memory barrier */
+ mb();
while ((in_be32(&phyregs->miimind) & MIIMIND_BUSY) && timeout--)
;
@@ -37,11 +38,13 @@
/* Clear the command register, and wait */
out_be32(&phyregs->miimcom, 0);
- asm("sync");
+ /* Memory barrier */
+ mb();
/* Initiate a read command, and wait */
out_be32(&phyregs->miimcom, MIIMCOM_READ_CYCLE);
- asm("sync");
+ /* Memory barrier */
+ mb();
/* Wait for the the indication that the read is done */
while ((in_be32(&phyregs->miimind) & (MIIMIND_NOTVALID | MIIMIND_BUSY))