ARM: DRA7: emif: Fix DDR init sequence during warm reset

Unlike OMAP5, EMIF PHY used in DRA7 will be left in unknown state after
warm reset, emif needs to be configured to bring it back to a known
state. So configure EMIF during warm reset.

Reported-by: Roger Quadros <rogerq@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
diff --git a/arch/arm/cpu/armv7/omap-common/emif-common.c b/arch/arm/cpu/armv7/omap-common/emif-common.c
index ca22c00..f5b22f6 100644
--- a/arch/arm/cpu/armv7/omap-common/emif-common.c
+++ b/arch/arm/cpu/armv7/omap-common/emif-common.c
@@ -1170,7 +1170,7 @@
 	 * Changing the timing registers in EMIF can happen(going from one
 	 * OPP to another)
 	 */
-	if (!(in_sdram || warm_reset())) {
+	if (!in_sdram && (!warm_reset() || is_dra7xx())) {
 		if (emif_sdram_type(regs->sdram_config) ==
 		    EMIF_SDRAM_TYPE_LPDDR2)
 			lpddr2_init(base, regs);
@@ -1178,7 +1178,7 @@
 			ddr3_init(base, regs);
 	}
 	if (warm_reset() && (emif_sdram_type(regs->sdram_config) ==
-	    EMIF_SDRAM_TYPE_DDR3)) {
+	    EMIF_SDRAM_TYPE_DDR3) && !is_dra7xx()) {
 		set_lpmode_selfrefresh(base);
 		emif_reset_phy(base);
 		omap5_ddr3_leveling(base, regs);