powerpc/mpc85xx: Add workaround for DDR erratum A004934
After DDR controller is enabled, it performs a calibration for the
transmit data vs DQS paths. During this calibration, the DDR controller
may make an inaccurate calculation, resulting in a non-optimal tap point.
Signed-off-by: York Sun <yorksun@freescale.com>
Signed-off-by: Andy Fleming <afleming@freescale.com>
diff --git a/arch/powerpc/cpu/mpc85xx/cmd_errata.c b/arch/powerpc/cpu/mpc85xx/cmd_errata.c
index ce5924b..2be192d 100644
--- a/arch/powerpc/cpu/mpc85xx/cmd_errata.c
+++ b/arch/powerpc/cpu/mpc85xx/cmd_errata.c
@@ -134,6 +134,9 @@
#ifdef CONFIG_SYS_FSL_ERRATUM_SRIO_A004034
puts("Work-around for Erratum SRIO-A004034 enabled\n");
#endif
+#ifdef CONFIG_SYS_FSL_ERRATUM_A_004934
+ puts("Work-around for Erratum A004934 enabled\n");
+#endif
return 0;
}