mmc: sunxi: Fix MMC clock parent selection
Most Allwinner SoCs which use the so called "new timing mode" in their
MMC controllers actually use the double-rate PLL6/PERIPH0 clock as their
parent input clock. This is interestingly enough compensated by a hidden
"by 2" post-divider in the mod clock, so the divider and actual output
rate stay the same.
Even though for the H6 and H616 (but only for them!) we use the doubled
input clock for the divider computation, we never accounted for the
implicit post-divider, so the clock was only half the speed on those SoCs.
This didn't really matter so far, as our slow MMIO routine limits the
transfer speed anyway, but we will fix this soon.
Clean up the code around that selection, to always use the normal PLL6
(PERIPH0(1x)) clock as an input. As the rate and divider are the same,
that makes no difference.
Explain the hardware differences in a comment.
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
2 files changed