| From 77894f28fb40126d8ffa927787e4258cac597191 Mon Sep 17 00:00:00 2001 |
| From: Peter Chiu <chui-hao.chiu@mediatek.com> |
| Date: Thu, 9 May 2024 11:16:10 +0800 |
| Subject: [PATCH 129/199] mtk: mt76: mt7996: add max mpdu len capability |
| |
| Set max mpdu len to 11454 according to hardware capability. |
| Without this patch, the max ampdu length would be 3895 and hurt performance. |
| |
| Signed-off-by: Peter Chiu <chui-hao.chiu@mediatek.com> |
| --- |
| mt7996/init.c | 4 +++- |
| 1 file changed, 3 insertions(+), 1 deletion(-) |
| |
| diff --git a/mt7996/init.c b/mt7996/init.c |
| index 2e624def..6e20a174 100644 |
| --- a/mt7996/init.c |
| +++ b/mt7996/init.c |
| @@ -1519,7 +1519,9 @@ mt7996_init_eht_caps(struct mt7996_phy *phy, enum nl80211_band band, |
| |
| eht_cap_elem->mac_cap_info[0] = |
| IEEE80211_EHT_MAC_CAP0_EPCS_PRIO_ACCESS | |
| - IEEE80211_EHT_MAC_CAP0_OM_CONTROL; |
| + IEEE80211_EHT_MAC_CAP0_OM_CONTROL | |
| + u8_encode_bits(IEEE80211_EHT_MAC_CAP0_MAX_MPDU_LEN_11454, |
| + IEEE80211_EHT_MAC_CAP0_MAX_MPDU_LEN_MASK); |
| |
| eht_cap_elem->phy_cap_info[0] = |
| IEEE80211_EHT_PHY_CAP0_NDP_4_EHT_LFT_32_GI | |
| -- |
| 2.18.0 |
| |