plat: marvell: armada: mcbin: squash several IO windows into one
There is no need to open tree different IO window when there is
possibility of having one covering required range.
Change-Id: I9feae1fc583df1f7d97d28161cf7601f43513856
Signed-off-by: Grzegorz Jaszczyk <jaz@semihalf.com>
diff --git a/plat/marvell/armada/a8k/a80x0_mcbin/board/marvell_plat_config.c b/plat/marvell/armada/a8k/a80x0_mcbin/board/marvell_plat_config.c
index b932967..75a1b0c 100644
--- a/plat/marvell/armada/a8k/a80x0_mcbin/board/marvell_plat_config.c
+++ b/plat/marvell/armada/a8k/a80x0_mcbin/board/marvell_plat_config.c
@@ -78,12 +78,8 @@
/* CP1 (MCI0) internal regs */
{0x00000000f4000000, 0x2000000, MCI_0_TID},
#ifndef IMAGE_BLE
- /* PCIe0 and SPI1_CS0 (RUNIT) on CP1*/
- {0x00000000f9000000, 0x2000000, MCI_0_TID},
- /* PCIe1 on CP1*/
- {0x00000000fb000000, 0x1000000, MCI_0_TID},
- /* PCIe2 on CP1*/
- {0x00000000fc000000, 0x1000000, MCI_0_TID},
+ /* PCIe0-2 and SPI1_CS0 (RUNIT) on CP1*/
+ {0x00000000f9000000, 0x4000000, MCI_0_TID},
/* MCI 0 indirect window */
{MVEBU_MCI_REG_BASE_REMAP(0), 0x100000, MCI_0_TID},
/* MCI 1 indirect window */