fix(st-clock): display proper PLL number for STM32MP13
The PLL clk_id does not start at 0, but it is in the enum listing all
clocks. To have a better display of the PLL number, start at PLL1,
by changing pll->clk_id in messages with pll->clk_id - _CK_PLL1 + 1.
Signed-off-by: Patrick Delaunay <patrick.delaunay@foss.st.com>
Change-Id: Ic09195ae6fe5f8d3a87e69962425f7c826f3670b
diff --git a/drivers/st/clk/clk-stm32mp13.c b/drivers/st/clk/clk-stm32mp13.c
index baa0770..1dbe841 100644
--- a/drivers/st/clk/clk-stm32mp13.c
+++ b/drivers/st/clk/clk-stm32mp13.c
@@ -1393,8 +1393,8 @@
/* Wait PLL lock */
while ((mmio_read_32(pll_base) & RCC_PLLNCR_PLLRDY) == 0U) {
if (timeout_elapsed(timeout)) {
- ERROR("%d clock start failed @ 0x%x: 0x%x\n",
- pll->clk_id, pll->reg_pllxcr, mmio_read_32(pll_base));
+ ERROR("PLL%d start failed @ 0x%x: 0x%x\n",
+ pll->clk_id - _CK_PLL1 + 1, pll->reg_pllxcr, mmio_read_32(pll_base));
return -EINVAL;
}
}
@@ -1411,8 +1411,8 @@
/* Wait PLL lock */
while ((mmio_read_32(pll_base) & RCC_PLLNCR_PLLRDY) != 0U) {
if (timeout_elapsed(timeout)) {
- ERROR("%d clock stop failed @ 0x%x: 0x%x\n",
- pll->clk_id, pll->reg_pllxcr, mmio_read_32(pll_base));
+ ERROR("PLL%d stop failed @ 0x%x: 0x%x\n",
+ pll->clk_id - _CK_PLL1 + 1, pll->reg_pllxcr, mmio_read_32(pll_base));
return -EINVAL;
}
}