plat: xilinx: zynqmp: Configure counter frequency during initialization

Counter frequency for generic timer of Arm-A53 based Application
Processing Unit(APU) is not configuring in case if First Stage Boot
Loader(FSBL) does not initialize counter frequency. This happens
when FSBL is running from Arm-R5 based Real-time Processing Unit(RPU).
Because of that generic timer driver functionality is not working.
So configure counter frequency during initialization.

Signed-off-by: Rajan Vaja <rajan.vaja@xilinx.com>
Change-Id: Icfccd59d7d2340fba25ebfb2ef6a813af4290896