fix(fvp): fdts: fix memtimer subframe addressing
The arm,armv7-timer-mem DT binding documentation demands that the
#size-cells property should be <1> only.
Adjust the value to be <1> and drop the now needless leading 0 in the
frame's reg property. Convert to #address-cell = <1> on the way.
Also adjust the interrupts property to use the proper GIC macros.
Change-Id: Ia2224663b1e6aaa7cf94af777473641de6a840d2
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
diff --git a/fdts/fvp-base-psci-common.dtsi b/fdts/fvp-base-psci-common.dtsi
index cf75c95..d75c007 100644
--- a/fdts/fvp-base-psci-common.dtsi
+++ b/fdts/fvp-base-psci-common.dtsi
@@ -173,13 +173,14 @@
compatible = "arm,armv7-timer-mem";
reg = <0x0 0x2a810000 0x0 0x10000>;
clock-frequency = <100000000>;
- #address-cells = <2>;
- #size-cells = <2>;
- ranges;
+ #address-cells = <1>;
+ #size-cells = <1>;
+ ranges = <0x0 0x0 0x2a810000 0x100000>;
+
frame@2a830000 {
frame-number = <1>;
- interrupts = <0 26 4>;
- reg = <0x0 0x2a830000 0x0 0x10000>;
+ interrupts = <GIC_SPI 26 IRQ_TYPE_LEVEL_HIGH>;
+ reg = <0x20000 0x10000>;
};
};